3 SKUs — 10, 20, 40 racks per module. Cold-climate, dry-climate, indoor-data-hall scenarios. PUE as low as 1.1.
| SKU | Racks | IT load | Cooling |
|---|---|---|---|
| E2F-R10-100 | 10 | 100 kW | 120 kW |
| E2F-R20-200 | 20 | 200 kW | 2×120 kW |
| E2F-R40-400 | 40 | 400 kW | 4×120 kW |
RakworX prefab natural-air-cooling Modular Data Centre — fully integrated, factory-tested, and pre-configured for plug-and-play deployment. 7 SKUs across Indoor, Outdoor, and High-Density series. PUE as low as 1.1. Edge / branch / on-prem / hybrid scenarios.
Each RakworX module is factory-built with full power, cooling, fire suppression, and structured cabling. Ship as a 20/40/50ft container, on-site lift into place, energize. No on-site trades, no weather delay, no scope creep. Three work modes adapt to the climate.
Direct use of outside air. Cold and dry climates — the cheapest cooling available. PUE as low as 1.1.
Mix cabinet exhaust with outside air. Increase intake temperature, reduce humidity. Spring / autumn climates.
Evaporative cooling plus DX refrigeration. Hot and humid climates — Southeast Asia, Middle East, equatorial deployments.
Internal recirculation. Air isolation from outside pollution, salt, dust, and extreme weather. Heavy-industry adjacencies.
7 SKUs from 10 racks to 40 racks per module. Indoor (natural-air only), Outdoor (with supplemental cooling for harsh climates), and High Density (40-50 kVA/rack for AI / HPC workloads).
3 SKUs — 10, 20, 40 racks per module. Cold-climate, dry-climate, indoor-data-hall scenarios. PUE as low as 1.1.
| SKU | Racks | IT load | Cooling |
|---|---|---|---|
| E2F-R10-100 | 10 | 100 kW | 120 kW |
| E2F-R20-200 | 20 | 200 kW | 2×120 kW |
| E2F-R40-400 | 40 | 400 kW | 4×120 kW |
3 SKUs — 10, 20, 40 racks per module. Hot / humid / dusty climates — Southeast Asia, Middle East, tropical. All-weather enclosures.
| SKU | Racks | IT load | Cooling |
|---|---|---|---|
| E2F-R10-100D | 10 | 100 kW | 120 kW + supp. |
| E2F-R20-200D | 20 | 200 kW | 2×120 kW + supp. |
| E2F-R40-400D | 40 | 400 kW | 4×120 kW + supp. |
1 SKU — 12 racks at 40-50 kVA each. Wider 930 mm rack format for GPU / accelerator density. Liquid-cooling ready.
| SKU | Racks | IT load | Cooling |
|---|---|---|---|
| E2F-R12-600D | 12 | 500 kW | 600 kW + supp. |
Modular, efficient, pre-engineered — built on real operating experience, not slideware.
Data hall units, power systems, cooling systems, and controls are all modular and standardized. Expand horizontally as load grows.
Natural-air cooling module delivers high-efficiency operation. PUE as low as 1.1 in cold-climate Indoor deployments.
All components factory-tested and integrated. Design-to-order capabilities. Single lift, single commissioning — no on-site trade coordination.
Up to 500 kW per single module. Up to 50 kW per rack. Deploy as needed — add another module when load grows. Friendly working environment for IT O&M.
Centralized remote operation. Real-time monitoring of power, cooling, environment, PUE. Optional IT monitoring module.
R12-600D variant delivers 40-50 kVA per rack — GPU / accelerator / HPC-ready. Wider 930 mm rack format, liquid-cooling ready.
Reduces construction time, water consumption, and electricity. Energy-saving natural cooling cuts recurring OpEx vs traditional DC builds.
RakworX modular architecture solves a specific class of problem: places where a traditional data centre building cannot be built — quickly, remotely, or at the required density.
Plug-and-play data centre for branch offices, retail, healthcare clinics. No on-site construction crew required.
Factory-floor data collection, MES hosting, OT/IT convergence. Outdoor (D-series) enclosures handle dust, vibration, industrial atmosphere.
Hospital PACS / EMR hosting, lab data, telemedicine back-end. Rapid-deploy alternative to traditional build.
Forward-deployed computing, hardened installations, mission-critical edge. All-weather enclosures for remote or coastal sites.
Short-term capacity for events, peak loads, disaster recovery. Deploy in days, redeploy when done.
Operational data hosting for aviation, maritime, rail. No building permits for permanent construction in many jurisdictions.
AGH is the certified channel partner for RakworX across Hong Kong and APAC. We don't drop-ship containers — we engineer. Our team sizes the power and cooling, supervises on-site lift and commissioning, integrates with existing facility power / network / BMS, and supports the full operating life.
Delivery is bilingual — English / Simplified / Traditional. Compliance documentation available in CQC, MIIT, and Tier-III Uptime formats for cross-border project handovers.
30 minutes with our team. We'll review your climate, IT load, footprint, and timeline — and propose an Indoor / Outdoor / High-Density SKU fit. No commitment.
Book a Discovery Call